Research ArticleBrain
Hyperecho-Turbo Spin-Echo Sequences at 3T: Clinical Application in Neuroradiology
R.H. Tetzlaff, I. Mader, W. Küker, J. Weber, S. Ziyeh, A. Schulze-Bonhage, J. Hennig and M. Weigel
American Journal of Neuroradiology May 2008, 29 (5) 956-961; DOI: https://doi.org/10.3174/ajnr.A0971
R.H. Tetzlaff
I. Mader
W. Küker
J. Weber
S. Ziyeh
A. Schulze-Bonhage
J. Hennig

References
- ↵Hennig J, Nauerth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986;3:823–33
- ↵
- ↵Hennig J, Weigel M, Scheffler K. Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS). Magn Reson Med 2003;49:527–35
- ↵Weigel M, Hennig J. Contrast behavior and relaxation effects of conventional and hyperecho-turbo spin echo sequences at 1.5 and 3 T. Magn Reson Med 2006;55:826–35
- Hennig J, Scheffler K. Hyperechoes. Magn Reson Med 2001;46:6–12
- ↵
- ↵Hennig J. Multiecho imaging sequences with low refocusing flip angles. J Magn Reson 1988;78:397–407
- ↵
- ↵Hennig J. Echoes: how to generate, recognize, use or avoid them in MR-imaging sequences. Concepts in Magnetic Resonance 1991;3:125–43
- ↵Weisskoff RM. Simple measurement of scanner stability for functional NMR imaging of activation in the brain. Magn Reson Med 1996;36:643–45
- ↵
- ↵Balaban RS, Ceckler TL. Magnetization transfer contrast in magnetic resonance imaging. Magn Reson Q 1992;8:116–37
- Duewell S, Wolff SD, Wen H, et al. MR imaging contrast in human brain tissue: assessment and optimization at 4 T. Radiology 1996;199:780–86
- Henkelman RM, Stanisz GJ, Graham SJ. Magnetization transfer in MRI: a review. NMR Biomed 2001;14:57–64
- Melki PS, Mulkern RV. Magnetization transfer effects in multislice RARE sequences. Magn Reson Med 1992;24:189–95
- Ordidge RJ, Gorell JM, Deniau JC, et al. Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 Tesla. Magn Reson Med 1994;32:335–41
- ↵
In this issue
Advertisement
R.H. Tetzlaff, I. Mader, W. Küker, J. Weber, S. Ziyeh, A. Schulze-Bonhage, J. Hennig, M. Weigel
Hyperecho-Turbo Spin-Echo Sequences at 3T: Clinical Application in Neuroradiology
American Journal of Neuroradiology May 2008, 29 (5) 956-961; DOI: 10.3174/ajnr.A0971
0 Responses
Jump to section
Related Articles
- No related articles found.
Cited By...
- No citing articles found.
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement