Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

OtherSpine Imaging and Spine Image-Guided Interventions

Intraspinal Leakage of Bone Cement after Vertebroplasty: A Report of 3 Cases

M.M.H. Teng, H. Cheng, D.M.-T. Ho and C.-Y. Chang
American Journal of Neuroradiology January 2006, 27 (1) 224-229;
M.M.H. Teng
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Cheng
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D.M.-T. Ho
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C.-Y. Chang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Article Figures & Data

Figures

  • Fig 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 1.

    Case 1. A, Sagittal reconstructed CT scan performed same day as vertebroplasty shows postvertebroplasty appearance with hyperattenuated bone cement in T8, T10, and L1 vertebral bodies. Bone cement filled the anterior vertebral body, the posterior vertebral body, and the epidural space (arrows). The technical flaw in this case was allowing the bone cement to fill the posterior vertebral body and continue filling in the spinal canal.

    B, Axial view at T7/T8 disk level performed same day as vertebroplasty shows bone cement in the epidural space (black arrows) and pulmonary arteries (white arrows).

    C, T2-weighted MR imaging performed 50 days after vertebroplasty shows low-signal-intensity bone cement inside the anterior and posterior aspects of T8, T10, and L1 vertebral bodies (white arrows) and postlaminectomy appearance with bloody fluid collection (white arrowheads) causing posterior epidural compression to the spinal cord. There is high-signal- intensity change in the spinal cord on the T2-weighted images, because of compressive myelopathy or previous thermal injury. The posterior epidural compression and signal intensity change of the spinal cord are similar to the MR imaging performed 5 days after the second decompressive surgery. These changes were not present on MR imaging performed 2 days before vertebroplasty.

    D, Fibrosis of arachnoid membrane (H&E stain).

  • Fig 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 2.

    Case 2. Lumbar spine plain films and MR imaging were taken 8 months after vertebroplasty.

    A, AP view conventional radiograph of lumbar spine.

    B, Lateral view conventional radiograph of lumbar spine.

    C, Sagittal MR imaging.

    D and E, Axial MR imaging.

    There is hyperattenuated bone cement in L2 vertebral body and in the spinal canal (arrows) on the anteroposterior and lateral conventional radiographs (A and B). On the proton-weighted image (C) and T2-weighted image (D and E), bone cement is low in signal intensity. Bone cement is found inside the dural sac in C and D (arrow). Needle tract can be identified as a low-signal-intensity channel (arrows) in the vertebral body extending posteriorly to the epidural space (E). The technical flaw in this case was puncturing the epidural space with the needle allowing cement to extend posteriorly to the epidural space along the needle tract.

  • Fig 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 3.

    Case 3. MR imaging taken 73 days after vertebroplasty (A–D) and conventional radiographs of lumbar spine (E and F) taken 86 days after vertebroplasty. Dense bone cement is found in the anterior and posterior aspects of the vertebral body (white arrows), epidural space (short arrow), and intervertebral foramen (arrows). The technical flaw of this vertebroplasty was use of the wrong needle and possibly drilling past the epidural space.

    G, Arachnoid membrane shows active fibrosis and thickening (H&E stain).

    H, Epidural soft tissue shows fat necrosis and focal chronic inflammatory cell infiltration (H&E stain).

PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 27 (1)
American Journal of Neuroradiology
Vol. 27, Issue 1
January, 2006
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Intraspinal Leakage of Bone Cement after Vertebroplasty: A Report of 3 Cases
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
M.M.H. Teng, H. Cheng, D.M.-T. Ho, C.-Y. Chang
Intraspinal Leakage of Bone Cement after Vertebroplasty: A Report of 3 Cases
American Journal of Neuroradiology Jan 2006, 27 (1) 224-229;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Intraspinal Leakage of Bone Cement after Vertebroplasty: A Report of 3 Cases
M.M.H. Teng, H. Cheng, D.M.-T. Ho, C.-Y. Chang
American Journal of Neuroradiology Jan 2006, 27 (1) 224-229;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Case Reports
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Large intraspinal cement leak during multilevel cement-augmented screw fixation
  • Pulmonary embolism with coexistent incidental pulmonary cement embolism post vertebroplasty
  • Sacral bone cyst treatment resulting in paraplegia
  • Use and evaluation of a semi-permeable mesh implant in vertebral augmentation for the treatment of painful osteoporotic vertebral compression fractures
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Optimization of Photon Counting CT Myelography
  • Characteristics of SIH Type I Culprit Lesions
  • Management Outcomes For VO Spine Biopsy
Show more Spine Imaging and Spine Image-Guided Interventions

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire