Research ArticleNeurointervention
A Report of the Clinical Use of the Detach-18 Mechanical Detachable Platinum Coil in 41 Patients
Kieran J. Murphy, Emmanuel Houdart, Kazimierz T. Szopinski, Olivier Levrier, Leopoldo Guimaraens, Dietmar Kühne, László Solymosi, Niels J. Bartholdy, Kenji Sugiu and Daniel A. Rüfenacht
American Journal of Neuroradiology February 2001, 22 (2) 341-344;
Kieran J. Murphy
Emmanuel Houdart
Kazimierz T. Szopinski
Olivier Levrier
Leopoldo Guimaraens
Dietmar Kühne
László Solymosi
Niels J. Bartholdy
Kenji Sugiu

References
- ↵Guglielmi G, Viñuela F. Intracranial aneurysms: Guglielmi electrothrombotic coils. Neurosurg Clin N Am 1994;5:427-435
- Guglielmi G. Viñuela F, Briganti F, Duckwiler G. Carotid-cavernous fistula caused by a ruptured intracavernous aneurysm: endovascular treatment by electrothrombosis with detachable coils. Neurosurgery 1992;31:591-596
- Guglielmi G, Viñuela F, Duckwiler G, et al. Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils. J Neurosurg 1992;77:515-524
- Halbach VV, Higashida RT, Barnwell SL, Dowd CF, Hieshima GB. Transarterial platinum coil embolization of carotid-cavernous fistulas. AJNR Am J Neuroradiol 1991;12:429-433
- Kuether TA, Nesbit GM, Barnwell SL. Clinical and angiographic outcomes, with treatment data, for patients with cerebral aneurysms treated with Guglielmi detachable coils: a single-center experience. Neurosurgery 1998;43:1016-1025
- McDougall CG, Halbach VV, Dowd CF, Higashida RT, Larsen DW, Hieshima GB. Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils. J Neurosurg 1996;84:393-399
- Nesbit GM, Barnwell SL. The use of electrolytically detachable coils in treating arteriovenous fistulas. AJNR Am J Neuroradiol 1998;19:1565-1569
- Raymond J, Roy D, Bojanowski M, Moumdjian R, L'Esperance G. Endovascular treatment of acutely ruptured and unruptured aneurysms of the basilar bifurcation. J Neurosurg 1997;86:211-219
- Vanninen R, Koivisto T, Saari T, Hernesniemi J, Vapalahti M. Ruptured intracranial aneurysms: acute endovascular treatment with electrolytically detachable coils: a prospective randomized study. Radiology 1999;211:325-336
- ↵
- Guglielmi G. Viñuela F, Sepetka I, Macellari V. Electrothrombosis of saccular aneurysms via endovascular approach: part 1. electrochemical basis, technique, and experimental results. J Neurosurg 1991;75:1-7
- Guglielmi G. Viñuela F, Dion J, Duckwiler G. Electrothrombosis of saccular aneurysms via endovascular approach: part 2. preliminary clinical results. J Neurosurg 1991;75:8-14
- Viñuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997;86:475-482
- ↵Cekirge HS, Saatci I, Firat MM, Balkanci F, Besim A. Interlocking detachable coil occlusion in the endovascular treatment of intracranial aneurysms: preliminary results. AJNR Am J Neuroradiol 1996;17:1651-1657
- Cognard C, Pierot L, Boulin A, et al. Intracranial aneurysms: endovascular treatment with mechanically detachable spirals in 60 aneurysms. Radiology 1997;202:738-792
- Marks MP, Chee H, Liddell RP, Steinberg GK, Panahian N, Lane B. A mechanically detachable coil for the treatment of aneurysms and occlusion of blood vessels. AJNR Am J Neuroradiol 1994;15:821-827
- Terada T, Kinoshita Y, Yokote H, et al. Clinical use of mechanical detachable coils for dural arteriovenous fistula. AJNR Am J Neuroradiol 1996;17:1343-1348
- Tornade A, Courtheoux P, Sengel C, Ozgulle A, Tajahmady T. Saccular intracranial aneurysms: endovascular treatment with mechanica detachable spiral coils. Radiology 1997;202:481-486
- Yoshimura S, Hashimoto N, Kazekawa K, Nishi S, Sampie K. Embolization of dural arteriovenous fistulas with interlocking detachable coils. AJNR Am J Neuroradiol 1995;16:322-324
- ↵Weill A, Ducros V, Cognard C, Piotin M, Moret J. “Corrosion” of tungsten spirals: a disturbing finding. Presented a the Annual Meeting of the American Society of Neuroradiology, San Diego, May 23–28, 1999;
- ↵Piotin M, Mandai S, Murphy KJ, et al. Dense packing of cerebral aneurysms: an in-vitro study with detachable platinum coils. AJNR Am J Neuroradiol 2000;21:757-760
In this issue
Advertisement
Kieran J. Murphy, Emmanuel Houdart, Kazimierz T. Szopinski, Olivier Levrier, Leopoldo Guimaraens, Dietmar Kühne, László Solymosi, Niels J. Bartholdy, Kenji Sugiu, Daniel A. Rüfenacht
A Report of the Clinical Use of the Detach-18 Mechanical Detachable Platinum Coil in 41 Patients
American Journal of Neuroradiology Feb 2001, 22 (2) 341-344;
0 Responses
A Report of the Clinical Use of the Detach-18 Mechanical Detachable Platinum Coil in 41 Patients
Kieran J. Murphy, Emmanuel Houdart, Kazimierz T. Szopinski, Olivier Levrier, Leopoldo Guimaraens, Dietmar Kühne, László Solymosi, Niels J. Bartholdy, Kenji Sugiu, Daniel A. Rüfenacht
American Journal of Neuroradiology Feb 2001, 22 (2) 341-344;
Jump to section
Related Articles
- No related articles found.
Cited By...
- No citing articles found.
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement