Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Abstract

MR appearance of Virchow-Robin spaces along lenticulostriate arteries: spin-echo and two-dimensional fast low-angle shot imaging.

N Hirabuki, N Fujita, K Fujii, T Hashimoto and T Kozuka
American Journal of Neuroradiology February 1994, 15 (2) 277-281;
N Hirabuki
Department of Radiology, Osaka University Medical School, Japan.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
N Fujita
Department of Radiology, Osaka University Medical School, Japan.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
K Fujii
Department of Radiology, Osaka University Medical School, Japan.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T Hashimoto
Department of Radiology, Osaka University Medical School, Japan.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T Kozuka
Department of Radiology, Osaka University Medical School, Japan.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • PDF
Loading

Abstract

PURPOSE To delineate the appearance of normal Virchow-Robin spaces on routine spin-echo images and demonstrate the lenticulostriate arteries within them with a flow-sensitive fast low-angle shot (FLASH) pulse sequence.

METHODS Seventy subjects, free of cerebrovascular diseases and other neurologic disorders, ranging in age from 1 to 75 years, were examined. On a 1.5-T MR system, axial spin-echo images of 5 mm thickness were obtained in all subjects. In 45 of 70 subjects axial two-dimensional FLASH images of 3 mm thickness were continuously imaged.

RESULTS On T1- and spin density-weighted images Virchow-Robin spaces were detected as small foci of cerebrospinal fluid intensity around the anterior commissure in all subjects (100%), and in the basal ganglia at the level of the foramen of Monro in 40 (57%). T2-weighted images equally showed Virchow-Robin spaces around the anterior commissure but were less sensitive than T1- and spin-density weighted images at the level of the foramen of Monro (14%). Virchow-Robin spaces identified on T2-weighted images should be isointense with cerebrospinal fluid. However, one or two spaces in 11 younger subjects were hypointense relative to adjacent brain tissue. On FLASH images most Virchow-Robin spaces identified on spin-echo images were delineated as high-intensity foci, corresponding to lenticulostriate arteries.

CONCLUSIONS Normal Virchow-Robin spaces along the lenticulostriate arteries are frequently detected on spin-echo images. Their appearance, affected by the flow of associated lenticulostriate arteries, varies from hyper- to hypointensity to brain tissue on T2-weighted images. The two-dimensional FLASH sequence can demonstrate the flow of the arteries, thereby helping confirm that these are truly Virchow-Robin spaces.

  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 15, Issue 2
1 Feb 1994
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
MR appearance of Virchow-Robin spaces along lenticulostriate arteries: spin-echo and two-dimensional fast low-angle shot imaging.
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
N Hirabuki, N Fujita, K Fujii, T Hashimoto, T Kozuka
MR appearance of Virchow-Robin spaces along lenticulostriate arteries: spin-echo and two-dimensional fast low-angle shot imaging.
American Journal of Neuroradiology Feb 1994, 15 (2) 277-281;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
MR appearance of Virchow-Robin spaces along lenticulostriate arteries: spin-echo and two-dimensional fast low-angle shot imaging.
N Hirabuki, N Fujita, K Fujii, T Hashimoto, T Kozuka
American Journal of Neuroradiology Feb 1994, 15 (2) 277-281;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Characterization of MR Imaging-Visible Perivascular Spaces in the White Matter of Healthy Adolescents at 3T
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire