More articles from Adult Brain
- Pipeline Embolization Device in the Treatment of Recurrent Previously Stented Cerebral Aneurysms
Twenty-one patients with previously stented recurrent aneurysms who later underwent Pipeline Embolization Device placement (group 1) were retrospectively identified and compared with 63 patients who had treatment with the Pipeline with no prior stent placement (group 2). Pipeline treatment resulted in complete aneurysm occlusion in 55.6% of patients in group 1 versus 80.4% of patients in group 2. The retreatment rate in group 1 was 11.1% versus 7.1% in group 2. The authors conclude that the Pipeline is less effective in the management of previously stented aneurysms than when used in nonstented aneurysms.
- Lateral Asymmetry and Spatial Difference of Iron Deposition in the Substantia Nigra of Patients with Parkinson Disease Measured with Quantitative Susceptibility Mapping
The authors evaluated 24 patients with Parkinson disease and 24 age- and sex-matched healthy controls who underwent 3T MR imaging with a 3D multiecho gradient-echo sequence. On reconstructed quantitative susceptibility maps they measured the susceptibility values in the anterior, middle, and posterior parts of the substantia nigra, the whole substantia nigra, and other deep gray matter structures in both cerebral hemispheres. Susceptibility in the middle part, the posterior part, and the whole substantia nigra was significantly higher in the more and the less affected hemibrains of patients with Parkinson disease than in the healthy controls. Also, susceptibility was significantly higher in the posterior substantia nigra of the more affected hemibrain.
- The Added Value of Volume-of-Interest C-Arm CT Imaging during Endovascular Treatment of Intracranial Aneurysms
VOI C-arm CT images were obtained in 28 patients undergoing endovascular treatment of intracranial aneurysms and the VOI images were reconstructed by using a novel prototype reconstruction algorithm to minimize truncation artifacts from double collimation. The reconstruction accuracy of VOI C-arm CT images was assessed quantitatively by comparing them with the full-head noncollimated images. Quality of VOI C-arm CT images was comparable with that of the standard Feldkamp, Davis, and Kress reconstruction of noncollimated C-arm CT images. The authors conclude that VOI imaging allows multiple 3D C-arm CT acquisitions and provides information related to device expansion, parent wall apposition, and neck coverage during the procedure, with very low additional radiation exposure to the patient.
- A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo
T1-weighted enhanced brain imaging was performed in 24 pediatric patients comparing the reference Cartesian TSE sequence (2 minutes 30 seconds) with a spiral spin-echo sequence (1 minutes 18 seconds) with similar spatial resolution and coverage. In 23/24 cases, spiral spin-echo was scored better than Cartesian TSE for flow artifact reduction and in 21 cases was superior in subjective preference. The authors demonstrate a relatively simple 2D spiral SE approach in T1-weighted postcontrast brain MR imaging that has minimal flow artifacts in comparison with its 2D Cartesian TSE counterpart.