Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

ReplyLetter

Reply:

Jody Tanabe
American Journal of Neuroradiology January 2025, DOI: https://doi.org/10.3174/ajnr.A8649
Jody Tanabe
aUniversity of Colorado-AnschutzMedical Campus, Aurora, Colorado
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site

We thank Dirk Smeets for his interest in our article and AJNR for the opportunity to respond. Regarding sample size, our study is in line with previous work comparing the effect of a report with no report on accuracy among clinical readers. Our study had the same or more cognitively healthy (CN) participants as in similar prior studies.1,-,3 Most interesting, it was the CN group in which the report was associated with lower accuracy. These prior studies had 3–9 readers, including trainees and non-neuroradiologists. To mirror actual practice, we had 4 neuroradiology attendings. Smeets cited an FDA database as the basis for the total number of examinations and readers necessary to demonstrate improved performance, presumably for FDA approval; however, it is not clear whether the FDA measure consists of a comparison of radiologists’ diagnoses with-versus-without a report. Still, we agree that a larger sample is needed. The reality as noted in the article cited by Smeets is that MRMC studies “are quite expensive to conduct, requiring a good deal of readers’ time for image interpretation.”4

Regarding the validity of a control cohort of patients with subjective memory symptoms, it is exactly this group that must be differentiated from patients with neurodegenerative disease. Second, volumetric analysis showed that the hippocampal, temporal lobe, parietal lobe, and whole-brain volume normalized volumes were higher in CN relative to patients with AD and FTD, suggesting that they were CN. Last, although it is possible that the CN group might develop AD in the future, it is conjecture at this time.

While our study did not demonstrate a change in the accuracy of neuroradiologists’ diagnoses with the report, we believe that quantitative volumetrics is superior to visual assessment in estimating brain volumes and advocate its use as an adjunct to clinical interpretation.

References

  1. 1.
    1. Hedderich DM,
    2. Dieckmeyer M,
    3. Andrisan T, et al
    . Normative brain volume reports may improve differential diagnosis of dementing neurodegenerative diseases in clinical practice. Eur Radiol 2020;30:2821–29 doi:10.1007/s00330-019-06602-0 pmid:32002640
  2. 2.
    1. Hedderich DM,
    2. Spiro JE,
    3. Goldhardt O, et al
    . Increasing diagnostic accuracy of mild cognitive impairment due to Alzheimer’s disease by user-independent, Web-based whole-brain volumetry. J Alzheimers Dis 2018;65:1459–67 doi:10.3233/JAD-180532 pmid:30175976
  3. 3.
    1. Pemberton HG,
    2. Goodkin O,
    3. Prados F, et al
    ; Alzheimer’s Disease Neuroimaging Initiative. Automated quantitative MRI volumetry reports support diagnostic interpretation in dementia: a multi-rater, clinical accuracy study. Eur Radiol 2021;31:5312–23 doi:10.1007/s00330-020-07455-8 pmid:33452627
  4. 4.
    1. Obuchowski NA,
    2. Bullen J
    . Multireader diagnostic accuracy imaging studies: fundamentals of design and analysis. Radiology 2022;303:26–34 doi:10.1148/radiol.211593 pmid:35166584
  • © 2025 by American Journal of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire