Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Getting new auth cookie, if you see this message a lot, tell someone!
ReplyLetter

Reply

R. Aviv, T.Y. Lee and M. Sharma
American Journal of Neuroradiology April 2012, 33 (4) E62; DOI: https://doi.org/10.3174/ajnr.A3051
R. Aviv
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.Y. Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Sharma
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site

We thank Drs Pulli and Yoo for their interest in our results and their subsequent confirmation of our study findings.1 Our work highlighted the danger of extrapolating findings from previous-generation scanners to newer, faster scanners. In particular, before our publication, there was an established opinion that CTA-signal intensities (SIs) were CBV-weighted and could, in addition to providing vascular data, provide an estimate of infarct core. This observation was true for older-generation scanners and was likely due to the increased scanning time required to cover the region of interest. Slower scanning times allowed contrast to reach the blood vessels in the ischemic/infarct region associated with prolonged transit time.

With the advent of modern scanners, the observation is no longer true. The role of CTA, in our opinion, remains the delineation of vascular anatomy, including the site of occlusion and presence of collaterals. CTA protocols should be optimized for vascular, not parenchymal, imaging. Estimation of infarct volume on CTA-SI was useful when CTP was not widely available but should be relegated to the history books. CTP studies provide outstanding estimates of core and tissue at risk with the area under the curve associated with thresholded parameters approaching 0.90 for core determination.2 For those centers where CTP is unavailable, we have shown that a postcontrast CT (PCT) following CTA demonstrates hypoattenuation that closely estimates core. PCT can be obtained at a lower dose than CTP. We strongly favor CTP over a PCT approach and have previously shown that infarct can be more confidently and correctly diagnosed by using CTP than noncontrast CT or CTA source images.3

References

  1. 1.
    1. Sharma M,
    2. Fox AJ,
    3. Symons S,
    4. et al
    . CT angiographic source images: flow- or volume-weighted? AJNR Am J Neuroradiol 2011;32: 359–64
  2. 2.
    1. Bivard A,
    2. Spratt N,
    3. Levi C,
    4. et al
    . Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke. Brain 2011;134: 3408–16
  3. 3.
    1. Hopyan J,
    2. Ciarallo A,
    3. Dowlatshahi D,
    4. et al
    . Certainty of stroke diagnosis: incremental benefit with CT perfusion over noncontrast CT and CT angiography. Radiology 2010;255: 142–53
  • © 2012 by American Journal of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire