Index by author
Zaharchuk, G.
- Adult BrainOpen AccessArterial Spin-Labeling Improves Detection of Intracranial Dural Arteriovenous Fistulas with MRIS.A. Amukotuwa, M.P. Marks, G. Zaharchuk, F. Calamante, R. Bammer and N. FischbeinAmerican Journal of Neuroradiology April 2018, 39 (4) 669-677; DOI: https://doi.org/10.3174/ajnr.A5570
Zerna, C.
- You have access“Delayed Pial Vessels” in Multiphase CT Angiography Aid in the Detection of Arterial Occlusion in Anterior CirculationR.-J. Singh, C. Zerna and B.K. MenonAmerican Journal of Neuroradiology April 2018, 39 (4) E47; DOI: https://doi.org/10.3174/ajnr.A5529
Zhang, L.
- FunctionalOpen AccessAltered Regional Homogeneity in Chronic Insomnia Disorder with or without Cognitive ImpairmentR. Pang, R. Guo, X. Wu, F. Hu, M. Liu, L. Zhang, Z. Wang and K. LiAmerican Journal of Neuroradiology April 2018, 39 (4) 742-747; DOI: https://doi.org/10.3174/ajnr.A5587
Zhang, M.
- Adult BrainOpen AccessPrediction of the Multisegment Clot Sign on Dynamic CT Angiography of Cardioembolic StrokeZ. Chen, F. Shi, M. Zhang, X. Gong, L. Lin and M. LouAmerican Journal of Neuroradiology April 2018, 39 (4) 663-668; DOI: https://doi.org/10.3174/ajnr.A5549
Zivadinov, R.
- Adult BrainYou have accessEvaluation of Leptomeningeal Contrast Enhancement Using Pre-and Postcontrast Subtraction 3D-FLAIR Imaging in Multiple SclerosisR. Zivadinov, D.P. Ramasamy, J. Hagemeier, C. Kolb, N. Bergsland, F. Schweser, M.G. Dwyer, B. Weinstock-Guttman and D. HojnackiAmerican Journal of Neuroradiology April 2018, 39 (4) 642-647; DOI: https://doi.org/10.3174/ajnr.A5541
Zwanenburg, J.J.M.
- EDITOR'S CHOICEADULT BRAINOpen AccessQuantification of Intracranial Aneurysm Volume Pulsation with 7T MRIR. Kleinloog, J.J.M. Zwanenburg, B. Schermers, E. Krikken, Y.M. Ruigrok, P.R. Luijten, F. Visser, L. Regli, G.J.E. Rinkel and B.H. VerweijAmerican Journal of Neuroradiology April 2018, 39 (4) 713-719; DOI: https://doi.org/10.3174/ajnr.A5546
Tenunruptured aneurysms in 9 patients were studied using a high-resolution 3D gradient-echo sequence with cardiac gating. Semiautomatic segmentation was used to measure aneurysm volume per cardiac phase. Aneurysm pulsation was defined as the relative increase in volume between the phase with the smallest volume and the phase with the largest volume. The accuracy and precision of the measured volume pulsations were addressed by digital phantom simulations and a repeat image analysis. In Stage II, the imaging protocol was optimized and 9 patients with 9 aneurysms were studied with and without administration of a contrast agent. Mean aneurysm pulsation in Stage I was 8%, with a mean volume change of 15 mm3. The artifactual volume pulsations measured with the digital phantom simulations were of the same magnitude as the volume pulsations observed in the patient data. Volume pulsation quantification with the current imaging protocol on 7T MR imaging is not accurate due to multiple imaging artifacts.