Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleHead and Neck Imaging

Volumetric Measurement for Comparison of the Accuracy between Intraoperative CT and Postoperative MR Imaging in Pituitary Adenoma Surgery

C.-C. Lee, S.-T. Lee, C.-N. Chang, P.-C. Pai, Y.-L. Chen, T.-C. Hsieh and C.-C. Chuang
American Journal of Neuroradiology September 2011, 32 (8) 1539-1544; DOI: https://doi.org/10.3174/ajnr.A2506
C.-C. Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S.-T. Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C.-N. Chang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P.-C. Pai
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y.-L. Chen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.-C. Hsieh
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C.-C. Chuang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: To improve the resection rate of unexpected residual pituitary tumor under image guidance, iCT provides a less time-consuming and more convenient approach of promising the safety of the trans-sphenoidal surgery. However, iCT was thought to have worse image quality than MR imaging. This study was designed to determine the predictive concordance of iCT with standard postoperative high-strength MR imaging for the detection of residual tumors.

MATERIALS AND METHODS: From February to December 2009, 33 patients with pituitary macroadenomas were enrolled in this prospective study. All patients received endoscopic trans-sphenoidal surgery for tumor removal and underwent iCT before the surgery finished. If an accessible tumor remnant was suspected and resectable, the surgery was continued. To assess the accuracy of intraoperative evaluation of tumor resection, the intraoperative findings were compared with MR imaging findings obtained 2 to 3 months after surgery by individually calculating the residual tumor volume.

RESULTS: There were no statistically significant differences in the comparison between iCT and postoperative MR imaging findings (P > .05), and the predictive rates were also high (R2 value >0.9). The GTR rate in the case of the noninvasive and fresh cases was 89% (17/19). The overall GTR rate was 58% (19/33), the second-look rate was 21% (7/33), and only one-fourth of the recurrent cases reached GTR.

CONCLUSIONS: The extent of resection in trans-sphenoidal surgery can be reliably assessed by iCT. Compared with postoperative MR imaging findings, the findings in this study provided quantitative evidence that iCT not only holds significant promise for maximizing the extent of tumor resection but also eliminates the unnecessary blind surgical manipulation, thus increasing the safety of the procedure.

Abbreviations

DLP
dose-length product
E
effective
GTR
gross-total tumor resection
iCT
intraoperative CT
iMR imaging
intraoperative MR imaging
NFPA
nonfunctioning pituitary adenoma
OR
operating room
STR
subtotal tumor resection
  • © 2011 by American Journal of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 32 (8)
American Journal of Neuroradiology
Vol. 32, Issue 8
1 Sep 2011
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Volumetric Measurement for Comparison of the Accuracy between Intraoperative CT and Postoperative MR Imaging in Pituitary Adenoma Surgery
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
C.-C. Lee, S.-T. Lee, C.-N. Chang, P.-C. Pai, Y.-L. Chen, T.-C. Hsieh, C.-C. Chuang
Volumetric Measurement for Comparison of the Accuracy between Intraoperative CT and Postoperative MR Imaging in Pituitary Adenoma Surgery
American Journal of Neuroradiology Sep 2011, 32 (8) 1539-1544; DOI: 10.3174/ajnr.A2506

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Volumetric Measurement for Comparison of the Accuracy between Intraoperative CT and Postoperative MR Imaging in Pituitary Adenoma Surgery
C.-C. Lee, S.-T. Lee, C.-N. Chang, P.-C. Pai, Y.-L. Chen, T.-C. Hsieh, C.-C. Chuang
American Journal of Neuroradiology Sep 2011, 32 (8) 1539-1544; DOI: 10.3174/ajnr.A2506
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • MRI of the Parasellar Ligaments
  • ASL Sensitivity for Head and Neck Paraganglioma
  • Post SRS Peritumoral Hyperintense Signal of VSs
Show more Head and Neck Imaging

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire