TABLE 2.

Results of carotid angioplasty and stenting for radiation-associated stenosis

PtVesselStenosis (%)StentSize (mm)Across BifurcationPrestent AngiographyPoststent AngiographyF/u (mo)Neurological Symptoms after StentingImaging Outcome
1RICA75Wallstent8 × 20NoYesYesNone
2LICA85Wallstent8 × 40YesYesYes61TIARestented
70Precise7 × 20No, LCCAYesNo17NoRestented
75Precise7 × 40No, LCCANoYes
3RCCA90Wallstent10 × 42NoYesYes76NoPatent
4LCCA70Wallstent8 × 40NoNoYes55NoPatent
5LICA80Wallstent10 × 40NoYesYes13NoRestented
70Wallstent6 × 20NoYesYes50NoPatent
RICA99Smart8 × 40NoYesYes22NoOccluded
6RICA75Wallstent6 × 20YesYesYes22NoPatent
7LCCA70NIR4 × 18NoNoYes14Stroke*Occluded
8RICA95Smart6 × 60YesYesYes34NoPatent
9LICA80Smart10 × 20NoYesNo32NoPatent
10LICA75Smart10 × 20NoYesYes11NoPatent
RICA95Smart6 × 20NoYesNo7NoPatent
11RICA95Smart9 × 30NoYesYes9NoPatent
LICA85Smart10 × 40NoYesNo8NoPatent
12LICA99Smart9 × 40NoYesNo16NoReangioplasty
13RICA90Smart9 × 30YesYesNo11NoPatent
14LCCA90Precise8 × 30NoYesNoNone
15LCCA95Precise, × 26 × 40, 6 × 20NoYesNo12NoPatent
16LICA80Precise8 × 20NoYesNo5NoPatent
  • Note.—Pt indicates patient; F/u, follow-up; R, right; L, left; ICA, internal carotid artery; CCA, common carotid artery; TIA, transient ischemic attack. Wallstent, NIR (Boston Scientific Corp., Natick, MA); Smart, Precise (Cordis Corp., Miami Lakes, FL).

  • * Stroke occurred shortly after patient developed atrial fibrillation.