Table 2:

Associations between subjective ipsilateral inner ear abnormalities and audiogram testing PTA and WRS

Subjective Ipsilateral Inner Ear SignalPTA (dB)P ValueWRS (%)P Value
T2 SPACE.03a.10
 Normal (12/23; 92.3%)31.683.9
 Abnormal (1/13; 7.7%)72.043.5
FLAIR.98.85
 Normal (3/12; 25.0%)40.072.7
 Abnormal (9/12; 75.0%)40.376.9
CISS.26.27
 Normal (3/11; 27.3%)20.0100.0
 Abnormal (8/11; 72.7%)23.186.5
  • a Statistically significant.